The ``pvsystem`` module contains functions for modeling the output and
performance of PV modules and inverters.
"""
from __future__ import division
import io
try:
from urllib2 import urlopen
except ImportError:
from urllib.request import urlopen
import numpy as np
import pandas as pd
from pvlib import tools
from pvlib.location import Location
from pvlib import irradiance, atmosphere
# not sure if this belongs in the pvsystem module.
# maybe something more like core.py? It may eventually grow to
# import a lot more functionality from other modules.
[docs]class PVSystem(object):
"""
The PVSystem class defines a standard set of PV system attributes
and modeling functions. This class describes the collection and
interactions of PV system components rather than an installed system
on the ground. It is typically used in combination with
:py:class:`~pvlib.location.Location` and
:py:class:`~pvlib.modelchain.ModelChain`
objects.
See the :py:class:`LocalizedPVSystem` class for an object model that
describes an installed PV system.
The class is complementary to the module-level functions.
The attributes should generally be things that don't change about
the system, such the type of module and the inverter. The instance
methods accept arguments for things that do change, such as
irradiance and temperature.
Parameters
----------
surface_tilt: float or array-like
Tilt angle of the module surface.
Up=0, horizon=90.
surface_azimuth: float or array-like
Azimuth angle of the module surface.
North=0, East=90, South=180, West=270.
albedo : None, float
The ground albedo. If ``None``, will attempt to use
``surface_type`` and ``irradiance.SURFACE_ALBEDOS``
to lookup albedo.
surface_type : None, string
The ground surface type. See ``irradiance.SURFACE_ALBEDOS``
for valid values.
module : None, string
The model name of the modules.
May be used to look up the module_parameters dictionary
via some other method.
module_parameters : None, dict or Series
Module parameters as defined by the SAPM, CEC, or other.
inverter : None, string
The model name of the inverters.
May be used to look up the inverter_parameters dictionary
via some other method.
inverter_parameters : None, dict or Series
Inverter parameters as defined by the SAPM, CEC, or other.
racking_model : None or string
Used for cell and module temperature calculations.
**kwargs
Arbitrary keyword arguments.
Included for compatibility, but not used.
See also
--------
pvlib.location.Location
pvlib.tracking.SingleAxisTracker
pvlib.pvsystem.LocalizedPVSystem
"""
def __init__(self,
surface_tilt=0, surface_azimuth=180,
albedo=None, surface_type=None,
module=None, module_parameters=None,
series_modules=None, parallel_modules=None,
inverter=None, inverter_parameters=None,
racking_model='open_rack_cell_glassback',
**kwargs):
self.surface_tilt = surface_tilt
self.surface_azimuth = surface_azimuth
# could tie these together with @property
self.surface_type = surface_type
if albedo is None:
self.albedo = irradiance.SURFACE_ALBEDOS.get(surface_type, 0.25)
else:
self.albedo = albedo
# could tie these together with @property
self.module = module
self.module_parameters = module_parameters
self.series_modules = series_modules
self.parallel_modules = parallel_modules
self.inverter = inverter
self.inverter_parameters = inverter_parameters
self.racking_model = racking_model
# needed for tying together Location and PVSystem in LocalizedPVSystem
super(PVSystem, self).__init__(**kwargs)
[docs] def get_aoi(self, solar_zenith, solar_azimuth):
"""Get the angle of incidence on the system.
Parameters
----------
solar_zenith : float or Series.
Solar zenith angle.
solar_azimuth : float or Series.
Solar azimuth angle.
Returns
-------
aoi : Series
The angle of incidence
"""
aoi = irradiance.aoi(self.surface_tilt, self.surface_azimuth,
solar_zenith, solar_azimuth)
return aoi
[docs] def get_irradiance(self, solar_zenith, solar_azimuth, dni, ghi, dhi,
dni_extra=None, airmass=None, model='haydavies',
**kwargs):
"""
Uses the :py:func:`irradiance.total_irrad` function to calculate
the plane of array irradiance components on a tilted surface
defined by ``self.surface_tilt``, ``self.surface_azimuth``, and
``self.albedo``.
Parameters
----------
solar_zenith : float or Series.
Solar zenith angle.
solar_azimuth : float or Series.
Solar azimuth angle.
dni : float or Series
Direct Normal Irradiance
ghi : float or Series
Global horizontal irradiance
dhi : float or Series
Diffuse horizontal irradiance
dni_extra : float or Series
Extraterrestrial direct normal irradiance
airmass : float or Series
Airmass
model : String
Irradiance model.
**kwargs
Passed to :func:`irradiance.total_irrad`.
Returns
-------
poa_irradiance : DataFrame
Column names are: ``total, beam, sky, ground``.
"""
# not needed for all models, but this is easier
if dni_extra is None:
dni_extra = irradiance.extraradiation(solar_zenith.index)
dni_extra = pd.Series(dni_extra, index=solar_zenith.index)
if airmass is None:
airmass = atmosphere.relativeairmass(solar_zenith)
return irradiance.total_irrad(self.surface_tilt,
self.surface_azimuth,
solar_zenith, solar_azimuth,
dni, ghi, dhi,
dni_extra=dni_extra, airmass=airmass,
model=model,
albedo=self.albedo,
**kwargs)
[docs] def ashraeiam(self, aoi):
"""
Determine the incidence angle modifier using
``self.module_parameters['b']``, ``aoi``,
and the :py:func:`ashraeiam` function.
Parameters
----------
aoi : numeric
The angle of incidence in degrees.
Returns
-------
modifier : numeric
The AOI modifier.
"""
b = self.module_parameters['b']
return ashraeiam(b, aoi)
[docs] def physicaliam(self, aoi):
"""
Determine the incidence angle modifier using
``self.module_parameters['K']``,
``self.module_parameters['L']``,
``self.module_parameters['n']``,
``aoi``, and the
:py:func:`physicaliam` function.
Parameters
----------
See pvsystem.physicaliam for details
Returns
-------
See pvsystem.physicaliam for details
"""
K = self.module_parameters['K']
L = self.module_parameters['L']
n = self.module_parameters['n']
return physicaliam(K, L, n, aoi)
[docs] def calcparams_desoto(self, poa_global, temp_cell, **kwargs):
"""
Use the :py:func:`calcparams_desoto` function, the input
parameters and ``self.module_parameters`` to calculate the
module currents and resistances.
Parameters
----------
poa_global : float or Series
The irradiance (in W/m^2) absorbed by the module.
temp_cell : float or Series
The average cell temperature of cells within a module in C.
**kwargs
See pvsystem.calcparams_desoto for details
Returns
-------
See pvsystem.calcparams_desoto for details
"""
return calcparams_desoto(poa_global, temp_cell,
self.module_parameters['alpha_sc'],
self.module_parameters,
self.module_parameters['EgRef'],
self.module_parameters['dEgdT'], **kwargs)
[docs] def sapm(self, poa_direct, poa_diffuse,
temp_cell, airmass_absolute, aoi, **kwargs):
"""
Use the :py:func:`sapm` function, the input parameters,
and ``self.module_parameters`` to calculate
Voc, Isc, Ix, Ixx, Vmp/Imp.
Parameters
----------
poa_direct : Series
The direct irradiance incident upon the module (W/m^2).
poa_diffuse : Series
The diffuse irradiance incident on module.
temp_cell : Series
The cell temperature (degrees C).
airmass_absolute : Series
Absolute airmass.
aoi : Series
Angle of incidence (degrees).
**kwargs
See pvsystem.sapm for details
Returns
-------
See pvsystem.sapm for details
"""
return sapm(self.module_parameters, poa_direct, poa_diffuse,
temp_cell, airmass_absolute, aoi)
# model now specified by self.racking_model
[docs] def sapm_celltemp(self, irrad, wind, temp):
"""Uses :py:func:`sapm_celltemp` to calculate module and cell
temperatures based on ``self.racking_model`` and
the input parameters.
Parameters
----------
See pvsystem.sapm_celltemp for details
Returns
-------
See pvsystem.sapm_celltemp for details
"""
return sapm_celltemp(irrad, wind, temp, self.racking_model)
[docs] def singlediode(self, photocurrent, saturation_current,
resistance_series, resistance_shunt, nNsVth):
"""Wrapper around the :py:func:`singlediode` function.
Parameters
----------
See pvsystem.singlediode for details
Returns
-------
See pvsystem.singlediode for details
"""
return singlediode(self.module_parameters, photocurrent,
saturation_current,
resistance_series, resistance_shunt, nNsVth)
[docs] def i_from_v(self, resistance_shunt, resistance_series, nNsVth, voltage,
saturation_current, photocurrent):
"""Wrapper around the :py:func:`i_from_v` function.
Parameters
----------
See pvsystem.i_from_v for details
Returns
-------
See pvsystem.i_from_v for details
"""
return i_from_v(resistance_shunt, resistance_series, nNsVth, voltage,
saturation_current, photocurrent)
# inverter now specified by self.inverter_parameters
[docs] def snlinverter(self, v_dc, p_dc):
"""Uses :func:`snlinverter` to calculate AC power based on
``self.inverter_parameters`` and the input parameters.
Parameters
----------
See pvsystem.snlinverter for details
Returns
-------
See pvsystem.snlinverter for details
"""
return snlinverter(self.inverter_parameters, v_dc, p_dc)
[docs] def localize(self, location=None, latitude=None, longitude=None,
**kwargs):
"""Creates a LocalizedPVSystem object using this object
and location data. Must supply either location object or
latitude, longitude, and any location kwargs
Parameters
----------
location : None or Location
latitude : None or float
longitude : None or float
**kwargs : see Location
Returns
-------
localized_system : LocalizedPVSystem
"""
if location is None:
location = Location(latitude, longitude, **kwargs)
return LocalizedPVSystem(pvsystem=self, location=location)
[docs]class LocalizedPVSystem(PVSystem, Location):
"""
The LocalizedPVSystem class defines a standard set of installed PV
system attributes and modeling functions. This class combines the
attributes and methods of the PVSystem and Location classes.
See the :py:class:`PVSystem` class for an object model that
describes an unlocalized PV system.
"""
def __init__(self, pvsystem=None, location=None, **kwargs):
# get and combine attributes from the pvsystem and/or location
# with the rest of the kwargs
if pvsystem is not None:
pv_dict = pvsystem.__dict__
else:
pv_dict = {}
if location is not None:
loc_dict = location.__dict__
else:
loc_dict = {}
new_kwargs = dict(list(pv_dict.items()) +
list(loc_dict.items()) +
list(kwargs.items()))
super(LocalizedPVSystem, self).__init__(**new_kwargs)
[docs]def systemdef(meta, surface_tilt, surface_azimuth, albedo, series_modules,
parallel_modules):
'''
Generates a dict of system parameters used throughout a simulation.
Parameters
----------
meta : dict
meta dict either generated from a TMY file using readtmy2 or
readtmy3, or a dict containing at least the following fields:
=============== ====== ====================
meta field format description
=============== ====== ====================
meta.altitude Float site elevation
meta.latitude Float site latitude
meta.longitude Float site longitude
meta.Name String site name
meta.State String state
meta.TZ Float timezone
=============== ====== ====================
surface_tilt : float or Series
Surface tilt angles in decimal degrees.
The tilt angle is defined as degrees from horizontal
(e.g. surface facing up = 0, surface facing horizon = 90)
surface_azimuth : float or Series
Surface azimuth angles in decimal degrees.
The azimuth convention is defined
as degrees east of north
(North=0, South=180, East=90, West=270).
albedo : float or Series
Ground reflectance, typically 0.1-0.4 for surfaces on Earth
(land), may increase over snow, ice, etc. May also be known as
the reflection coefficient. Must be >=0 and <=1.
series_modules : int
Number of modules connected in series in a string.
parallel_modules : int
Number of strings connected in parallel.
Returns
-------
Result : dict
A dict with the following fields.
* 'surface_tilt'
* 'surface_azimuth'
* 'albedo'
* 'series_modules'
* 'parallel_modules'
* 'latitude'
* 'longitude'
* 'tz'
* 'name'
* 'altitude'
See also
--------
pvlib.tmy.readtmy3
pvlib.tmy.readtmy2
'''
try:
name = meta['Name']
except KeyError:
name = meta['City']
system = {'surface_tilt': surface_tilt,
'surface_azimuth': surface_azimuth,
'albedo': albedo,
'series_modules': series_modules,
'parallel_modules': parallel_modules,
'latitude': meta['latitude'],
'longitude': meta['longitude'],
'tz': meta['TZ'],
'name': name,
'altitude': meta['altitude']}
return system
[docs]def ashraeiam(b, aoi):
'''
Determine the incidence angle modifier using the ASHRAE transmission
model.
ashraeiam calculates the incidence angle modifier as developed in
[1], and adopted by ASHRAE (American Society of Heating,
Refrigeration, and Air Conditioning Engineers) [2]. The model has
been used by model programs such as PVSyst [3].
Note: For incident angles near 90 degrees, this model has a
discontinuity which has been addressed in this function.
Parameters
----------
b : float
A parameter to adjust the modifier as a function of angle of
incidence. Typical values are on the order of 0.05 [3].
aoi : Series
The angle of incidence between the module normal vector and the
sun-beam vector in degrees.
Returns
-------
IAM : Series
The incident angle modifier calculated as 1-b*(sec(aoi)-1) as
described in [2,3].
Returns nan for all abs(aoi) >= 90 and for all IAM values
that would be less than 0.
References
----------
[1] Souka A.F., Safwat H.H., "Determindation of the optimum
orientations for the double exposure flat-plate collector and its
reflections". Solar Energy vol .10, pp 170-174. 1966.
[2] ASHRAE standard 93-77
[3] PVsyst Contextual Help.
http://files.pvsyst.com/help/index.html?iam_loss.htm retrieved on
September 10, 2012
See Also
--------
irradiance.aoi
physicaliam
'''
IAM = 1 - b*((1/np.cos(np.radians(aoi)) - 1))
IAM[abs(aoi) >= 90] = np.nan
IAM[IAM < 0] = np.nan
return IAM
[docs]def physicaliam(K, L, n, aoi):
'''
Determine the incidence angle modifier using refractive index,
glazing thickness, and extinction coefficient
physicaliam calculates the incidence angle modifier as described in
De Soto et al. "Improvement and validation of a model for
photovoltaic array performance", section 3. The calculation is based
upon a physical model of absorbtion and transmission through a
cover. Required information includes, incident angle, cover
extinction coefficient, cover thickness
Note: The authors of this function believe that eqn. 14 in [1] is
incorrect. This function uses the following equation in its place:
theta_r = arcsin(1/n * sin(theta))
Parameters
----------
K : float
The glazing extinction coefficient in units of 1/meters.
Reference [1] indicates that a value of 4 is reasonable for
"water white" glass. K must be a numeric scalar or vector with
all values >=0. If K is a vector, it must be the same size as
all other input vectors.
L : float
The glazing thickness in units of meters. Reference [1]
indicates that 0.002 meters (2 mm) is reasonable for most
glass-covered PV panels. L must be a numeric scalar or vector
with all values >=0. If L is a vector, it must be the same size
as all other input vectors.
n : float
The effective index of refraction (unitless). Reference [1]
indicates that a value of 1.526 is acceptable for glass. n must
be a numeric scalar or vector with all values >=0. If n is a
vector, it must be the same size as all other input vectors.
aoi : Series
The angle of incidence between the module normal vector and the
sun-beam vector in degrees.
Returns
-------
IAM : float or Series
The incident angle modifier as specified in eqns. 14-16 of [1].
IAM is a column vector with the same number of elements as the
largest input vector.
Theta must be a numeric scalar or vector. For any values of
theta where abs(aoi)>90, IAM is set to 0. For any values of aoi
where -90 < aoi < 0, theta is set to abs(aoi) and evaluated.
References
----------
[1] W. De Soto et al., "Improvement and validation of a model for
photovoltaic array performance", Solar Energy, vol 80, pp. 78-88,
2006.
[2] Duffie, John A. & Beckman, William A.. (2006). Solar Engineering
of Thermal Processes, third edition. [Books24x7 version] Available
from http://common.books24x7.com/toc.aspx?bookid=17160.
See Also
--------
getaoi
ephemeris
spa
ashraeiam
'''
thetar_deg = tools.asind(1.0 / n*(tools.sind(aoi)))
tau = (np.exp(- 1.0 * (K*L / tools.cosd(thetar_deg))) *
((1 - 0.5*((((tools.sind(thetar_deg - aoi)) ** 2) /
((tools.sind(thetar_deg + aoi)) ** 2) +
((tools.tand(thetar_deg - aoi)) ** 2) /
((tools.tand(thetar_deg + aoi)) ** 2))))))
zeroang = 1e-06
thetar_deg0 = tools.asind(1.0 / n*(tools.sind(zeroang)))
tau0 = (np.exp(- 1.0 * (K*L / tools.cosd(thetar_deg0))) *
((1 - 0.5*((((tools.sind(thetar_deg0 - zeroang)) ** 2) /
((tools.sind(thetar_deg0 + zeroang)) ** 2) +
((tools.tand(thetar_deg0 - zeroang)) ** 2) /
((tools.tand(thetar_deg0 + zeroang)) ** 2))))))
IAM = tau / tau0
IAM[abs(aoi) >= 90] = np.nan
IAM[IAM < 0] = np.nan
return IAM
[docs]def calcparams_desoto(poa_global, temp_cell, alpha_isc, module_parameters,
EgRef, dEgdT, M=1, irrad_ref=1000, temp_ref=25):
'''
Applies the temperature and irradiance corrections to inputs for
singlediode.
Applies the temperature and irradiance corrections to the IL, I0,
Rs, Rsh, and a parameters at reference conditions (IL_ref, I0_ref,
etc.) according to the De Soto et. al description given in [1]. The
results of this correction procedure may be used in a single diode
model to determine IV curves at irradiance = S, cell temperature =
Tcell.
Parameters
----------
poa_global : float or Series
The irradiance (in W/m^2) absorbed by the module.
temp_cell : float or Series
The average cell temperature of cells within a module in C.
alpha_isc : float
The short-circuit current temperature coefficient of the
module in units of 1/C.
module_parameters : dict
Parameters describing PV module performance at reference
conditions according to DeSoto's paper. Parameters may be
generated or found by lookup. For ease of use,
retrieve_sam can automatically generate a dict based on the
most recent SAM CEC module
database. The module_parameters dict must contain the
following 5 fields:
* a_ref - modified diode ideality factor parameter at
reference conditions (units of eV), a_ref can be calculated
from the usual diode ideality factor (n),
number of cells in series (Ns),
and cell temperature (Tcell) per equation (2) in [1].
* I_L_ref - Light-generated current (or photocurrent)
in amperes at reference conditions. This value is referred to
as Iph in some literature.
* I_o_ref - diode reverse saturation current in amperes,
under reference conditions.
* R_sh_ref - shunt resistance under reference conditions (ohms).
* R_s - series resistance under reference conditions (ohms).
EgRef : float
The energy bandgap at reference temperature (in eV).
1.121 eV for silicon. EgRef must be >0.
dEgdT : float
The temperature dependence of the energy bandgap at SRC (in
1/C). May be either a scalar value (e.g. -0.0002677 as in [1])
or a DataFrame of dEgdT values corresponding to each input
condition (this may be useful if dEgdT is a function of
temperature).
M : float or Series (optional, default=1)
An optional airmass modifier, if omitted, M is given a value of
1, which assumes absolute (pressure corrected) airmass = 1.5. In
this code, M is equal to M/Mref as described in [1] (i.e. Mref
is assumed to be 1). Source [1] suggests that an appropriate
value for M as a function absolute airmass (AMa) may be:
>>> M = np.polyval([-0.000126, 0.002816, -0.024459, 0.086257, 0.918093],
... AMa) # doctest: +SKIP
M may be a Series.
irrad_ref : float (optional, default=1000)
Reference irradiance in W/m^2.
temp_ref : float (optional, default=25)
Reference cell temperature in C.
Returns
-------
Tuple of the following results:
photocurrent : float or Series
Light-generated current in amperes at irradiance=S and
cell temperature=Tcell.
saturation_current : float or Series
Diode saturation curent in amperes at irradiance
S and cell temperature Tcell.
resistance_series : float
Series resistance in ohms at irradiance S and cell temperature
Tcell.
resistance_shunt : float or Series
Shunt resistance in ohms at irradiance S and cell temperature
Tcell.
nNsVth : float or Series
Modified diode ideality factor at irradiance S and cell
temperature Tcell. Note that in source [1] nNsVth = a (equation
2). nNsVth is the product of the usual diode ideality factor
(n), the number of series-connected cells in the module (Ns),
and the thermal voltage of a cell in the module (Vth) at a cell
temperature of Tcell.
References
----------
[1] W. De Soto et al., "Improvement and validation of a model for
photovoltaic array performance", Solar Energy, vol 80, pp. 78-88,
2006.
[2] System Advisor Model web page. https://sam.nrel.gov.
[3] A. Dobos, "An Improved Coefficient Calculator for the California
Energy Commission 6 Parameter Photovoltaic Module Model", Journal of
Solar Energy Engineering, vol 134, 2012.
[4] O. Madelung, "Semiconductors: Data Handbook, 3rd ed." ISBN
3-540-40488-0
See Also
--------
sapm
sapm_celltemp
singlediode
retrieve_sam
Notes
-----
If the reference parameters in the ModuleParameters struct are read
from a database or library of parameters (e.g. System Advisor
Model), it is important to use the same EgRef and dEgdT values that
were used to generate the reference parameters, regardless of the
actual bandgap characteristics of the semiconductor. For example, in
the case of the System Advisor Model library, created as described
in [3], EgRef and dEgdT for all modules were 1.121 and -0.0002677,
respectively.
This table of reference bandgap energies (EgRef), bandgap energy
temperature dependence (dEgdT), and "typical" airmass response (M)
is provided purely as reference to those who may generate their own
reference module parameters (a_ref, IL_ref, I0_ref, etc.) based upon
the various PV semiconductors. Again, we stress the importance of
using identical EgRef and dEgdT when generation reference parameters
and modifying the reference parameters (for irradiance, temperature,
and airmass) per DeSoto's equations.
Silicon (Si):
* EgRef = 1.121
* dEgdT = -0.0002677
>>> M = np.polyval([-1.26E-4, 2.816E-3, -0.024459, 0.086257, 0.918093],
... AMa) # doctest: +SKIP
Source: [1]
Cadmium Telluride (CdTe):
* EgRef = 1.475
* dEgdT = -0.0003
>>> M = np.polyval([-2.46E-5, 9.607E-4, -0.0134, 0.0716, 0.9196],
... AMa) # doctest: +SKIP
Source: [4]
Copper Indium diSelenide (CIS):
* EgRef = 1.010
* dEgdT = -0.00011
>>> M = np.polyval([-3.74E-5, 0.00125, -0.01462, 0.0718, 0.9210],
... AMa) # doctest: +SKIP
Source: [4]
Copper Indium Gallium diSelenide (CIGS):
* EgRef = 1.15
* dEgdT = ????
>>> M = np.polyval([-9.07E-5, 0.0022, -0.0202, 0.0652, 0.9417],
... AMa) # doctest: +SKIP
Source: Wikipedia
Gallium Arsenide (GaAs):
* EgRef = 1.424
* dEgdT = -0.000433
* M = unknown
Source: [4]
'''
M = np.max(M, 0)
a_ref = module_parameters['a_ref']
IL_ref = module_parameters['I_L_ref']
I0_ref = module_parameters['I_o_ref']
Rsh_ref = module_parameters['R_sh_ref']
Rs_ref = module_parameters['R_s']
k = 8.617332478e-05
Tref_K = temp_ref + 273.15
Tcell_K = temp_cell + 273.15
E_g = EgRef * (1 + dEgdT*(Tcell_K - Tref_K))
nNsVth = a_ref * (Tcell_K / Tref_K)
IL = (poa_global/irrad_ref) * M * (IL_ref + alpha_isc * (Tcell_K - Tref_K))
I0 = (I0_ref * ((Tcell_K / Tref_K) ** 3) *
(np.exp(EgRef / (k*(Tref_K)) - (E_g / (k*(Tcell_K))))))
Rsh = Rsh_ref * (irrad_ref / poa_global)
Rs = Rs_ref
return IL, I0, Rs, Rsh, nNsVth
[docs]def retrieve_sam(name=None, samfile=None):
'''
Retrieve latest module and inverter info from SAM website.
This function will retrieve either:
* CEC module database
* Sandia Module database
* CEC Inverter database
and return it as a pandas dataframe.
Parameters
----------
name : String
Name can be one of:
* 'CECMod' - returns the CEC module database
* 'CECInverter' - returns the CEC Inverter database
* 'SandiaInverter' - returns the CEC Inverter database
(CEC is only current inverter db available; tag kept for backwards
compatibility)
* 'SandiaMod' - returns the Sandia Module database
samfile : String
Absolute path to the location of local versions of the SAM file.
If file is specified, the latest versions of the SAM database
will not be downloaded. The selected file must be in .csv
format.
If set to 'select', a dialogue will open allowing the user to
navigate to the appropriate page.
Returns
-------
A DataFrame containing all the elements of the desired database.
Each column represents a module or inverter, and a specific dataset
can be retrieved by the command
Examples
--------
>>> from pvlib import pvsystem
>>> invdb = pvsystem.retrieve_sam(name='CECInverter')
>>> inverter = invdb.AE_Solar_Energy__AE6_0__277V__277V__CEC_2012_
>>> inverter
Vac 277.000000
Paco 6000.000000
Pdco 6165.670000
Vdco 361.123000
Pso 36.792300
C0 -0.000002
C1 -0.000047
C2 -0.001861
C3 0.000721
Pnt 0.070000
Vdcmax 600.000000
Idcmax 32.000000
Mppt_low 200.000000
Mppt_high 500.000000
Name: AE_Solar_Energy__AE6_0__277V__277V__CEC_2012_, dtype: float64
'''
if name is not None:
name = name.lower()
base_url = 'https://sam.nrel.gov/sites/sam.nrel.gov/files/'
if name == 'cecmod':
url = base_url + 'sam-library-cec-modules-2015-6-30.csv'
elif name == 'sandiamod':
url = base_url + 'sam-library-sandia-modules-2015-6-30.csv'
elif name in ['cecinverter', 'sandiainverter']:
# Allowing either, to provide for old code,
# while aligning with current expectations
url = base_url + 'sam-library-cec-inverters-2015-6-30.csv'
elif samfile is None:
raise ValueError('invalid name {}'.format(name))
if name is None and samfile is None:
raise ValueError('must supply name or samfile')
if samfile is None:
response = urlopen(url)
csvdata = io.StringIO(response.read().decode(errors='ignore'))
elif samfile == 'select':
try:
# python 2
import Tkinter as tkinter
from tkFileDialog import askopenfilename
except ImportError:
# python 3
import tkinter
from tkinter.filedialog import askopenfilename
tkinter.Tk().withdraw()
csvdata = askopenfilename()
else:
csvdata = samfile
return _parse_raw_sam_df(csvdata)
def _parse_raw_sam_df(csvdata):
df = pd.read_csv(csvdata, index_col=0, skiprows=[1, 2])
colnames = df.columns.values.tolist()
parsedcolnames = []
for cn in colnames:
parsedcolnames.append(cn.replace(' ', '_'))
df.columns = parsedcolnames
parsedindex = []
for index in df.index:
parsedindex.append(index.replace(' ', '_').replace('-', '_')
.replace('.', '_').replace('(', '_')
.replace(')', '_').replace('[', '_')
.replace(']', '_').replace(':', '_')
.replace('+', '_').replace('/', '_')
.replace('"', '_').replace(',', '_'))
df.index = parsedindex
df = df.transpose()
return df
[docs]def sapm(module, poa_direct, poa_diffuse, temp_cell, airmass_absolute, aoi):
'''
The Sandia PV Array Performance Model (SAPM) generates 5 points on a
PV module's I-V curve (Voc, Isc, Ix, Ixx, Vmp/Imp) according to
SAND2004-3535. Assumes a reference cell temperature of 25 C.
Parameters
----------
module : Series or dict
A DataFrame defining the SAPM performance parameters. See the
notes section for more details.
poa_direct : Series
The direct irradiance incident upon the module (W/m^2).
poa_diffuse : Series
The diffuse irradiance incident on module.
temp_cell : Series
The cell temperature (degrees C).
airmass_absolute : Series
Absolute airmass.
aoi : Series
Angle of incidence (degrees).
Returns
-------
A DataFrame with the columns:
* i_sc : Short-circuit current (A)
* I_mp : Current at the maximum-power point (A)
* v_oc : Open-circuit voltage (V)
* v_mp : Voltage at maximum-power point (V)
* p_mp : Power at maximum-power point (W)
* i_x : Current at module V = 0.5Voc, defines 4th point on I-V
curve for modeling curve shape
* i_xx : Current at module V = 0.5(Voc+Vmp), defines 5th point on
I-V curve for modeling curve shape
* effective_irradiance : Effective irradiance
Notes
-----
The coefficients from SAPM which are required in ``module`` are
listed in the following table.
The modules in the Sandia module database contain these
coefficients, but the modules in the CEC module database do not.
Both databases can be accessed using :py:func:`retrieve_sam`.
================ ========================================================
Key Description
================ ========================================================
A0-A4 The airmass coefficients used in calculating
effective irradiance
B0-B5 The angle of incidence coefficients used in calculating
effective irradiance
C0-C7 The empirically determined coefficients relating
Imp, Vmp, Ix, and Ixx to effective irradiance
Isco Short circuit current at reference condition (amps)
Impo Maximum power current at reference condition (amps)
Aisc Short circuit current temperature coefficient at
reference condition (1/C)
Aimp Maximum power current temperature coefficient at
reference condition (1/C)
Bvoco Open circuit voltage temperature coefficient at
reference condition (V/C)
Mbvoc Coefficient providing the irradiance dependence for the
BetaVoc temperature coefficient at reference irradiance
(V/C)
Bvmpo Maximum power voltage temperature coefficient at
reference condition
Mbvmp Coefficient providing the irradiance dependence for the
BetaVmp temperature coefficient at reference irradiance
(V/C)
N Empirically determined "diode factor" (dimensionless)
Cells_in_Series Number of cells in series in a module's cell string(s)
IXO Ix at reference conditions
IXXO Ixx at reference conditions
FD Fraction of diffuse irradiance used by module
================ ========================================================
References
----------
[1] King, D. et al, 2004, "Sandia Photovoltaic Array Performance
Model", SAND Report 3535, Sandia National Laboratories, Albuquerque,
NM.
See Also
--------
retrieve_sam
sapm_celltemp
'''
T0 = 25
q = 1.60218e-19 # Elementary charge in units of coulombs
kb = 1.38066e-23 # Boltzmann's constant in units of J/K
E0 = 1000
am_coeff = [module['A4'], module['A3'], module['A2'], module['A1'],
module['A0']]
aoi_coeff = [module['B5'], module['B4'], module['B3'], module['B2'],
module['B1'], module['B0']]
F1 = np.polyval(am_coeff, airmass_absolute)
F2 = np.polyval(aoi_coeff, aoi)
# Ee is the "effective irradiance"
Ee = F1 * ((poa_direct*F2 + module['FD']*poa_diffuse) / E0)
Ee.fillna(0, inplace=True)
Ee = Ee.clip_lower(0)
Bvmpo = module['Bvmpo'] + module['Mbvmp']*(1 - Ee)
Bvoco = module['Bvoco'] + module['Mbvoc']*(1 - Ee)
delta = module['N'] * kb * (temp_cell + 273.15) / q
dfout = pd.DataFrame(index=Ee.index)
dfout['i_sc'] = (
module['Isco'] * Ee * (1 + module['Aisc']*(temp_cell - T0))
)
dfout['i_mp'] = (
module['Impo'] * (module['C0']*Ee + module['C1']*(Ee**2)) *
(1 + module['Aimp']*(temp_cell - T0))
)
dfout['v_oc'] = (
module['Voco'] + module['Cells_in_Series']*delta*np.log(Ee) +
Bvoco*(temp_cell - T0)
).clip_lower(0)
dfout['v_mp'] = (
module['Vmpo'] +
module['C2']*module['Cells_in_Series']*delta*np.log(Ee) +
module['C3']*module['Cells_in_Series']*((delta*np.log(Ee)) ** 2) +
Bvmpo*(temp_cell - T0)
).clip_lower(0)
dfout['p_mp'] = dfout['i_mp'] * dfout['v_mp']
dfout['i_x'] = (module['IXO'] *
(module['C4']*Ee + module['C5']*(Ee**2)) *
(1 + module['Aisc']*(temp_cell - T0)))
# the Ixx calculation in King 2004 has a typo (mixes up Aisc and Aimp)
dfout['i_xx'] = (module['IXXO'] *
(module['C6']*Ee + module['C7']*(Ee**2)) *
(1 + module['Aisc']*(temp_cell - T0)))
dfout['effective_irradiance'] = Ee
return dfout
[docs]def sapm_celltemp(poa_global, wind_speed, temp_air,
model='open_rack_cell_glassback'):
'''
Estimate cell and module temperatures per the Sandia PV Array
Performance Model (SAPM, SAND2004-3535), from the incident
irradiance, wind speed, ambient temperature, and SAPM module
parameters.
Parameters
----------
poa_global : float or Series
Total incident irradiance in W/m^2.
wind_speed : float or Series
Wind speed in m/s at a height of 10 meters.
temp_air : float or Series
Ambient dry bulb temperature in degrees C.
model : string, list, or dict
Model to be used.
If string, can be:
* 'open_rack_cell_glassback' (default)
* 'roof_mount_cell_glassback'
* 'open_rack_cell_polymerback'
* 'insulated_back_polymerback'
* 'open_rack_polymer_thinfilm_steel'
* '22x_concentrator_tracker'
If dict, supply the following parameters
(if list, in the following order):
* a : float
SAPM module parameter for establishing the upper
limit for module temperature at low wind speeds and
high solar irradiance.
* b : float
SAPM module parameter for establishing the rate at
which the module temperature drops as wind speed increases
(see SAPM eqn. 11).
* deltaT : float
SAPM module parameter giving the temperature difference
between the cell and module back surface at the
reference irradiance, E0.
Returns
--------
DataFrame with columns 'temp_cell' and 'temp_module'.
Values in degrees C.
References
----------
[1] King, D. et al, 2004, "Sandia Photovoltaic Array Performance
Model", SAND Report 3535, Sandia National Laboratories, Albuquerque,
NM.
See Also
--------
sapm
'''
temp_models = {'open_rack_cell_glassback': [-3.47, -.0594, 3],
'roof_mount_cell_glassback': [-2.98, -.0471, 1],
'open_rack_cell_polymerback': [-3.56, -.0750, 3],
'insulated_back_polymerback': [-2.81, -.0455, 0],
'open_rack_polymer_thinfilm_steel': [-3.58, -.113, 3],
'22x_concentrator_tracker': [-3.23, -.130, 13]
}
if isinstance(model, str):
model = temp_models[model.lower()]
elif isinstance(model, list):
model = model
elif isinstance(model, (dict, pd.Series)):
model = [model['a'], model['b'], model['deltaT']]
a = model[0]
b = model[1]
deltaT = model[2]
E0 = 1000. # Reference irradiance
temp_module = pd.Series(poa_global*np.exp(a + b*wind_speed) + temp_air)
temp_cell = temp_module + (poa_global / E0)*(deltaT)
return pd.DataFrame({'temp_cell': temp_cell, 'temp_module': temp_module})
[docs]def singlediode(module, photocurrent, saturation_current,
resistance_series, resistance_shunt, nNsVth):
'''
Solve the single-diode model to obtain a photovoltaic IV curve.
Singlediode solves the single diode equation [1]
.. math::
I = IL - I0*[exp((V+I*Rs)/(nNsVth))-1] - (V + I*Rs)/Rsh
for ``I`` and ``V`` when given ``IL, I0, Rs, Rsh,`` and ``nNsVth
(nNsVth = n*Ns*Vth)`` which are described later. Returns a DataFrame
which contains the 5 points on the I-V curve specified in
SAND2004-3535 [3]. If all IL, I0, Rs, Rsh, and nNsVth are scalar, a
single curve will be returned, if any are Series (of the same
length), multiple IV curves will be calculated.
The input parameters can be calculated using calcparams_desoto from
meteorological data.
Parameters
----------
module : DataFrame
A DataFrame defining the SAPM performance parameters.
photocurrent : float or Series
Light-generated current (photocurrent) in amperes under desired
IV curve conditions. Often abbreviated ``I_L``.
saturation_current : float or Series
Diode saturation current in amperes under desired IV curve
conditions. Often abbreviated ``I_0``.
resistance_series : float or Series
Series resistance in ohms under desired IV curve conditions.
Often abbreviated ``Rs``.
resistance_shunt : float or Series
Shunt resistance in ohms under desired IV curve conditions.
Often abbreviated ``Rsh``.
nNsVth : float or Series
The product of three components. 1) The usual diode ideal factor
(n), 2) the number of cells in series (Ns), and 3) the cell
thermal voltage under the desired IV curve conditions (Vth). The
thermal voltage of the cell (in volts) may be calculated as
``k*temp_cell/q``, where k is Boltzmann's constant (J/K),
temp_cell is the temperature of the p-n junction in Kelvin, and
q is the charge of an electron (coulombs).
Returns
-------
If ``photocurrent`` is a Series, a DataFrame with the following
columns. All columns have the same number of rows as the largest
input DataFrame.
If ``photocurrent`` is a scalar, a dict with the following keys.
* i_sc - short circuit current in amperes.
* v_oc - open circuit voltage in volts.
* i_mp - current at maximum power point in amperes.
* v_mp - voltage at maximum power point in volts.
* p_mp - power at maximum power point in watts.
* i_x - current, in amperes, at ``v = 0.5*v_oc``.
* i_xx - current, in amperes, at ``V = 0.5*(v_oc+v_mp)``.
Notes
-----
The solution employed to solve the implicit diode equation utilizes
the Lambert W function to obtain an explicit function of V=f(i) and
I=f(V) as shown in [2].
References
-----------
[1] S.R. Wenham, M.A. Green, M.E. Watt, "Applied Photovoltaics" ISBN
0 86758 909 4
[2] A. Jain, A. Kapoor, "Exact analytical solutions of the
parameters of real solar cells using Lambert W-function", Solar
Energy Materials and Solar Cells, 81 (2004) 269-277.
[3] D. King et al, "Sandia Photovoltaic Array Performance Model",
SAND2004-3535, Sandia National Laboratories, Albuquerque, NM
See also
--------
sapm
calcparams_desoto
'''
# Find short circuit current using Lambert W
i_sc = i_from_v(resistance_shunt, resistance_series, nNsVth, 0.01,
saturation_current, photocurrent)
params = {'r_sh': resistance_shunt,
'r_s': resistance_series,
'nNsVth': nNsVth,
'i_0': saturation_current,
'i_l': photocurrent}
__, v_oc = _golden_sect_DataFrame(params, 0, module['V_oc_ref']*1.6,
_v_oc_optfcn)
p_mp, v_mp = _golden_sect_DataFrame(params, 0, module['V_oc_ref']*1.14,
_pwr_optfcn)
# Invert the Power-Current curve. Find the current where the inverted power
# is minimized. This is i_mp. Start the optimization at v_oc/2
i_mp = i_from_v(resistance_shunt, resistance_series, nNsVth, v_mp,
saturation_current, photocurrent)
# Find Ix and Ixx using Lambert W
i_x = i_from_v(resistance_shunt, resistance_series, nNsVth,
0.5*v_oc, saturation_current, photocurrent)
i_xx = i_from_v(resistance_shunt, resistance_series, nNsVth,
0.5*(v_oc+v_mp), saturation_current, photocurrent)
# @wholmgren: need to move this stuff to a different function
# If the user says they want a curve of with number of points equal to
# NumPoints (must be >=2), then create a voltage array where voltage is
# zero in the first column, and Voc in the last column. Number of columns
# must equal NumPoints. Each row represents the voltage for one IV curve.
# Then create a current array where current is Isc in the first column, and
# zero in the last column, and each row represents the current in one IV
# curve. Thus the nth (V,I) point of curve m would be found as follows:
# (Result.V(m,n),Result.I(m,n)).
# if NumPoints >= 2
# s = ones(1,NumPoints); # shaping DataFrame to shape the column
# # DataFrame parameters into 2-D matrices
# Result.V = (Voc)*(0:1/(NumPoints-1):1);
# Result.I = I_from_V(Rsh*s, Rs*s, nNsVth*s, Result.V, I0*s, IL*s);
# end
dfout = {}
dfout['i_sc'] = i_sc
dfout['i_mp'] = i_mp
dfout['v_oc'] = v_oc
dfout['v_mp'] = v_mp
dfout['p_mp'] = p_mp
dfout['i_x'] = i_x
dfout['i_xx'] = i_xx
try:
dfout = pd.DataFrame(dfout, index=photocurrent.index)
except AttributeError:
pass
return dfout
# Created April,2014
# Author: Rob Andrews, Calama Consulting
def _golden_sect_DataFrame(params, VL, VH, func):
'''
Vectorized golden section search for finding MPPT
from a dataframe timeseries.
Parameters
----------
params : dict
Dictionary containing scalars or arrays
of inputs to the function to be optimized.
Each row should represent an independent optimization.
VL: float
Lower bound of the optimization
VH: float
Upper bound of the optimization
func: function
Function to be optimized must be in the form f(array-like, x)
Returns
-------
func(df,'V1') : DataFrame
function evaluated at the optimal point
df['V1']: Dataframe
Dataframe of optimal points
Notes
-----
This funtion will find the MAXIMUM of a function
'''
df = params
df['VH'] = VH
df['VL'] = VL
err = df['VH'] - df['VL']
errflag = True
iterations = 0
while errflag:
phi = (np.sqrt(5)-1)/2*(df['VH']-df['VL'])
df['V1'] = df['VL'] + phi
df['V2'] = df['VH'] - phi
df['f1'] = func(df, 'V1')
df['f2'] = func(df, 'V2')
df['SW_Flag'] = df['f1'] > df['f2']
df['VL'] = df['V2']*df['SW_Flag'] + df['VL']*(~df['SW_Flag'])
df['VH'] = df['V1']*~df['SW_Flag'] + df['VH']*(df['SW_Flag'])
err = df['V1'] - df['V2']
try:
errflag = (abs(err) > .01).all()
except ValueError:
errflag = (abs(err) > .01)
iterations += 1
if iterations > 50:
raise Exception("EXCEPTION:iterations exeeded maximum (50)")
return func(df, 'V1'), df['V1']
def _pwr_optfcn(df, loc):
'''
Function to find power from ``i_from_v``.
'''
I = i_from_v(df['r_sh'], df['r_s'], df['nNsVth'],
df[loc], df['i_0'], df['i_l'])
return I*df[loc]
def _v_oc_optfcn(df, loc):
'''
Function to find the open circuit voltage from ``i_from_v``.
'''
I = -abs(i_from_v(df['r_sh'], df['r_s'], df['nNsVth'],
df[loc], df['i_0'], df['i_l']))
return I
[docs]def i_from_v(resistance_shunt, resistance_series, nNsVth, voltage,
saturation_current, photocurrent):
'''
Calculates current from voltage per Eq 2 Jain and Kapoor 2004 [1].
Parameters
----------
resistance_shunt : float or Series
Shunt resistance in ohms under desired IV curve conditions.
Often abbreviated ``Rsh``.
resistance_series : float or Series
Series resistance in ohms under desired IV curve conditions.
Often abbreviated ``Rs``.
nNsVth : float or Series
The product of three components. 1) The usual diode ideal factor
(n), 2) the number of cells in series (Ns), and 3) the cell
thermal voltage under the desired IV curve conditions (Vth). The
thermal voltage of the cell (in volts) may be calculated as
``k*temp_cell/q``, where k is Boltzmann's constant (J/K),
temp_cell is the temperature of the p-n junction in Kelvin, and
q is the charge of an electron (coulombs).
voltage : float or Series
The voltage in Volts under desired IV curve conditions.
saturation_current : float or Series
Diode saturation current in amperes under desired IV curve
conditions. Often abbreviated ``I_0``.
photocurrent : float or Series
Light-generated current (photocurrent) in amperes under desired
IV curve conditions. Often abbreviated ``I_L``.
Returns
-------
current : np.array
References
----------
[1] A. Jain, A. Kapoor, "Exact analytical solutions of the
parameters of real solar cells using Lambert W-function", Solar
Energy Materials and Solar Cells, 81 (2004) 269-277.
'''
try:
from scipy.special import lambertw
except ImportError:
raise ImportError('This function requires scipy')
Rsh = resistance_shunt
Rs = resistance_series
I0 = saturation_current
IL = photocurrent
V = voltage
argW = (Rs*I0*Rsh *
np.exp(Rsh*(Rs*(IL+I0)+V) / (nNsVth*(Rs+Rsh))) /
(nNsVth*(Rs + Rsh)))
lambertwterm = lambertw(argW)
# Eqn. 4 in Jain and Kapoor, 2004
I = -V/(Rs + Rsh) - (nNsVth/Rs)*lambertwterm + Rsh*(IL + I0)/(Rs + Rsh)
return I.real
[docs]def snlinverter(inverter, v_dc, p_dc):
'''
Converts DC power and voltage to AC power using Sandia's
Grid-Connected PV Inverter model.
Determines the AC power output of an inverter given the DC voltage,
DC power, and appropriate Sandia Grid-Connected Photovoltaic
Inverter Model parameters. The output, ac_power, is clipped at the
maximum power output, and gives a negative power during low-input
power conditions, but does NOT account for maximum power point
tracking voltage windows nor maximum current or voltage limits on
the inverter.
Parameters
----------
inverter : DataFrame
A DataFrame defining the inverter to be used, giving the
inverter performance parameters according to the Sandia
Grid-Connected Photovoltaic Inverter Model (SAND 2007-5036) [1].
A set of inverter performance parameters are provided with
pvlib, or may be generated from a System Advisor Model (SAM) [2]
library using retrievesam.
Required DataFrame columns are:
====== ============================================================
Column Description
====== ============================================================
Pac0 AC-power output from inverter based on input power
and voltage (W)
Pdc0 DC-power input to inverter, typically assumed to be equal
to the PV array maximum power (W)
Vdc0 DC-voltage level at which the AC-power rating is achieved
at the reference operating condition (V)
Ps0 DC-power required to start the inversion process, or
self-consumption by inverter, strongly influences inverter
efficiency at low power levels (W)
C0 Parameter defining the curvature (parabolic) of the
relationship between ac-power and dc-power at the reference
operating condition, default value of zero gives a
linear relationship (1/W)
C1 Empirical coefficient allowing Pdco to vary linearly
with dc-voltage input, default value is zero (1/V)
C2 Empirical coefficient allowing Pso to vary linearly with
dc-voltage input, default value is zero (1/V)
C3 Empirical coefficient allowing Co to vary linearly with
dc-voltage input, default value is zero (1/V)
Pnt AC-power consumed by inverter at night (night tare) to
maintain circuitry required to sense PV array voltage (W)
====== ============================================================
v_dc : float or Series
DC voltages, in volts, which are provided as input to the
inverter. Vdc must be >= 0.
p_dc : float or Series
A scalar or DataFrame of DC powers, in watts, which are provided
as input to the inverter. Pdc must be >= 0.
Returns
-------
ac_power : float or Series
Modeled AC power output given the input DC voltage, Vdc, and
input DC power, Pdc. When ac_power would be greater than Pac0,
it is set to Pac0 to represent inverter "clipping". When
ac_power would be less than Ps0 (startup power required), then
ac_power is set to -1*abs(Pnt) to represent nightly power
losses. ac_power is not adjusted for maximum power point
tracking (MPPT) voltage windows or maximum current limits of the
inverter.
References
----------
[1] SAND2007-5036, "Performance Model for Grid-Connected
Photovoltaic Inverters by D. King, S. Gonzalez, G. Galbraith, W.
Boyson
[2] System Advisor Model web page. https://sam.nrel.gov.
See also
--------
sapm
singlediode
'''
Paco = inverter['Paco']
Pdco = inverter['Pdco']
Vdco = inverter['Vdco']
Pso = inverter['Pso']
C0 = inverter['C0']
C1 = inverter['C1']
C2 = inverter['C2']
C3 = inverter['C3']
Pnt = inverter['Pnt']
A = Pdco * (1 + C1*(v_dc - Vdco))
B = Pso * (1 + C2*(v_dc - Vdco))
C = C0 * (1 + C3*(v_dc - Vdco))
# ensures that function works with scalar or Series input
p_dc = pd.Series(p_dc)
ac_power = (Paco/(A-B) - C*(A-B)) * (p_dc-B) + C*((p_dc-B)**2)
ac_power[ac_power > Paco] = Paco
ac_power[ac_power < Pso] = - 1.0 * abs(Pnt)
if len(ac_power) == 1:
ac_power = ac_power.ix[0]
return ac_power