pvlib.pvsystem.pvsyst_celltemp¶
-
pvlib.pvsystem.
pvsyst_celltemp
(poa_global, temp_air, wind_speed=1.0, eta_m=0.1, alpha_absorption=0.9, model_params='freestanding')[source]¶ Calculate cell temperature using an emperical heat loss factor model as implemented in PVsyst.
The heat loss factors provided through the ‘model_params’ argument represent the combined effect of convection, radiation and conduction, and their values are experimentally determined.
Parameters: - poa_global : numeric
Total incident irradiance in W/m^2.
- temp_air : numeric
Ambient dry bulb temperature in degrees C.
- wind_speed : numeric, default 1.0
Wind speed in m/s measured at the same height for which the wind loss factor was determined. The default value is 1.0, which is the wind speed at module height used to determine NOCT.
- eta_m : numeric, default 0.1
Module external efficiency as a fraction, i.e., DC power / poa_global.
- alpha_absorption : numeric, default 0.9
Absorption coefficient
- model_params : string, tuple, or list (no dict), default ‘freestanding’
Heat loss factors to be used.
If string, can be:
- ‘freestanding’ (default)
- Modules with rear surfaces exposed to open air (e.g. rack mounted).
- ‘insulated’
- Modules with rear surfaces in close proximity to another surface (e.g. roof mounted).
If tuple/list, supply parameters in the following order:
- constant_loss_factor : float
- Combined heat loss factor coefficient. Freestanding default is 29, fully insulated arrays is 15.
- wind_loss_factor : float
- Combined heat loss factor influenced by wind. Default is 0.
Returns: - temp_cell : numeric or Series
Cell temperature in degrees Celsius
References
[1]”PVsyst 6 Help”, Files.pvsyst.com, 2018. [Online]. Available: http://files.pvsyst.com/help/index.html. [Accessed: 10- Dec- 2018].
[2] Faiman, D. (2008). “Assessing the outdoor operating temperature of photovoltaic modules.” Progress in Photovoltaics 16(4): 307-315.