pvlib.tracking.SingleAxisTracker¶
-
class
pvlib.tracking.
SingleAxisTracker
(axis_tilt=0, axis_azimuth=0, max_angle=90, backtrack=True, gcr=0.2857142857142857, cross_axis_tilt=0.0, **kwargs)[source]¶ A class for single-axis trackers that inherits the PV modeling methods from
PVSystem
. For details on calculating tracker rotation seepvlib.tracking.singleaxis()
.- Parameters
axis_tilt (float, default 0) – The tilt of the axis of rotation (i.e, the y-axis defined by axis_azimuth) with respect to horizontal, in decimal degrees.
axis_azimuth (float, default 0) – A value denoting the compass direction along which the axis of rotation lies. Measured in decimal degrees east of north.
max_angle (float, default 90) – A value denoting the maximum rotation angle, in decimal degrees, of the one-axis tracker from its horizontal position (horizontal if axis_tilt = 0). A max_angle of 90 degrees allows the tracker to rotate to a vertical position to point the panel towards a horizon. max_angle of 180 degrees allows for full rotation.
backtrack (bool, default True) – Controls whether the tracker has the capability to “backtrack” to avoid row-to-row shading. False denotes no backtrack capability. True denotes backtrack capability.
gcr (float, default 2.0/7.0) – A value denoting the ground coverage ratio of a tracker system which utilizes backtracking; i.e. the ratio between the PV array surface area to total ground area. A tracker system with modules 2 meters wide, centered on the tracking axis, with 6 meters between the tracking axes has a gcr of 2/6=0.333. If gcr is not provided, a gcr of 2/7 is default. gcr must be <=1.
cross_axis_tilt (float, default 0.0) – The angle, relative to horizontal, of the line formed by the intersection between the slope containing the tracker axes and a plane perpendicular to the tracker axes. Cross-axis tilt should be specified using a right-handed convention. For example, trackers with axis azimuth of 180 degrees (heading south) will have a negative cross-axis tilt if the tracker axes plane slopes down to the east and positive cross-axis tilt if the tracker axes plane slopes up to the east. Use
calc_cross_axis_tilt()
to calculate cross_axis_tilt. [degrees]**kwargs – Passed to
PVSystem
.
See also
pvlib.tracking.singleaxis
,pvlib.tracking.calc_axis_tilt
,pvlib.tracking.calc_cross_axis_tilt
Methods
__init__
([axis_tilt, axis_azimuth, …])Initialize self.
adrinverter
(v_dc, p_dc)Uses
pvlib.inverter.adr()
to calculate AC power based onself.inverter_parameters
and the input voltage and power.calcparams_cec
(effective_irradiance, …)Use the
calcparams_cec()
function, the input parameters andself.module_parameters
to calculate the module currents and resistances.calcparams_desoto
(effective_irradiance, …)Use the
calcparams_desoto()
function, the input parameters andself.module_parameters
to calculate the module currents and resistances.calcparams_pvsyst
(effective_irradiance, …)Use the
calcparams_pvsyst()
function, the input parameters andself.module_parameters
to calculate the module currents and resistances.faiman_celltemp
(poa_global, temp_air[, …])Use
temperature.faiman()
to calculate cell temperature.first_solar_spectral_loss
(pw, airmass_absolute)Use the
first_solar_spectral_correction()
function to calculate the spectral loss modifier.fuentes_celltemp
(poa_global, temp_air, …)Use
temperature.fuentes()
to calculate cell temperature.get_aoi
(surface_tilt, surface_azimuth, …)Get the angle of incidence on the system.
get_iam
(aoi[, iam_model])Determine the incidence angle modifier using the method specified by
iam_model
.get_irradiance
(surface_tilt, …[, …])Uses the
irradiance.get_total_irradiance()
function to calculate the plane of array irradiance components on a tilted surface defined by the input data andself.albedo
.i_from_v
(resistance_shunt, …)Wrapper around the
pvlib.pvsystem.i_from_v()
function.localize
([location, latitude, longitude])Deprecated since version 0.8.
pvsyst_celltemp
(poa_global, temp_air[, …])Uses
temperature.pvsyst_cell()
to calculate cell temperature.pvwatts_ac
(pdc)Calculates AC power according to the PVWatts model using
pvlib.inverter.pvwatts()
, self.module_parameters[“pdc0”], and eta_inv_nom=self.inverter_parameters[“eta_inv_nom”].pvwatts_dc
(g_poa_effective, temp_cell)Calcuates DC power according to the PVWatts model using
pvlib.pvsystem.pvwatts_dc()
, self.module_parameters[‘pdc0’], and self.module_parameters[‘gamma_pdc’].Calculates DC power losses according the PVwatts model using
pvlib.pvsystem.pvwatts_losses()
andself.losses_parameters
.sapm
(effective_irradiance, temp_cell, **kwargs)Use the
sapm()
function, the input parameters, andself.module_parameters
to calculate Voc, Isc, Ix, Ixx, Vmp, and Imp.sapm_celltemp
(poa_global, temp_air, wind_speed)Uses
temperature.sapm_cell()
to calculate cell temperatures.sapm_effective_irradiance
(poa_direct, …[, …])Use the
sapm_effective_irradiance()
function, the input parameters, andself.module_parameters
to calculate effective irradiance.sapm_spectral_loss
(airmass_absolute)Use the
sapm_spectral_loss()
function, the input parameters, andself.module_parameters
to calculate F1.Scales the voltage, current, and power of the data DataFrame by self.modules_per_string and self.strings_per_inverter.
singleaxis
(apparent_zenith, apparent_azimuth)Get tracking data.
singlediode
(photocurrent, …[, ivcurve_pnts])Wrapper around the
pvlib.pvsystem.singlediode()
function.snlinverter
(v_dc, p_dc)Uses
pvlib.inverter.sandia()
to calculate AC power based onself.inverter_parameters
and the input voltage and power.