pvlib.temperature.sapm_cell_from_module

pvlib.temperature.sapm_cell_from_module(module_temperature, poa_global, deltaT, irrad_ref=1000)[source]

Calculate cell temperature from module temperature using the Sandia Array Performance Model.

See [1] for details on the Sandia Array Performance Model.

Parameters:
  • module_temperature (numeric) – Temperature of back of module surface [C].
  • poa_global (numeric) – Total incident irradiance [W/m^2].
  • deltaT (float) – Parameter \(\Delta T\) in (2) [C].
  • irrad_ref (float, default 1000) – Reference irradiance, parameter \(E_{0}\) in (2) [W/m^2].
Returns:

numeric, values in degrees C.

Notes

The model for cell temperature \(T_{C}\) is given by Eq. 12 in [1].

\[T_{C} = T_{m} + \frac{E}{E_{0}} \Delta T\]

The module back surface temperature \(T_{m}\) is implemented in sapm_module().

Model parameters depend both on the module construction and its mounting. Parameter sets are provided in [1] for representative modules and mounting, and are coded for convenience in pvlib.temperature.TEMPERATURE_MODEL_PARAMETERS.

Module Mounting a b \(\Delta T [C]\)
glass/glass open rack -3.47 -0.0594 3
glass/glass close roof -2.98 -0.0471 1
glass/polymer open rack -3.56 -0.075 3
glass/polymer insulated back -2.81 -0.0455 0

References

[1](1, 2, 3) King, D. et al, 2004, “Sandia Photovoltaic Array Performance Model”, SAND Report 3535, Sandia National Laboratories, Albuquerque, NM.