pvlib.temperature.pvsyst_cell#

pvlib.temperature.pvsyst_cell(poa_global, temp_air, wind_speed=1.0, u_c=29.0, u_v=0.0, module_efficiency=0.1, alpha_absorption=0.9)[source]#

Calculate cell temperature using an empirical heat loss factor model as implemented in PVsyst.

Parameters
  • poa_global (numeric) – Total incident irradiance [W/m^2].

  • temp_air (numeric) – Ambient dry bulb temperature [C].

  • wind_speed (numeric, default 1.0) – Wind speed in m/s measured at the same height for which the wind loss factor was determined. The default value 1.0 m/s is the wind speed at module height used to determine NOCT. [m/s]

  • u_c (float, default 29.0) – Combined heat loss factor coefficient. The default value is representative of freestanding modules with the rear surfaces exposed to open air (e.g., rack mounted). Parameter \(U_{c}\) in (1). \(\left[\frac{\text{W}/{\text{m}^2}}{\text{C}}\right]\)

  • u_v (float, default 0.0) – Combined heat loss factor influenced by wind. Parameter \(U_{v}\) in (1). \(\left[ \frac{\text{W}/\text{m}^2}{\text{C}\ \left( \text{m/s} \right)} \right]\)

  • module_efficiency (numeric, default 0.1) – Module external efficiency as a fraction. Parameter \(\eta_{m}\) in (1). Calculate as \(\eta_{m} = DC\ power / (POA\ irradiance \times module\ area)\).

  • alpha_absorption (numeric, default 0.9) – Absorption coefficient. Parameter \(\alpha\) in (1).

Returns

numeric, values in degrees Celsius

Notes

The Pvsyst model for cell temperature \(T_{C}\) is given by

(1)#\[ T_{C} = T_{a} + \frac{\alpha E (1 - \eta_{m})}{U_{c} + U_{v} \times WS}\]

Inputs to the model are plane-of-array irradiance \(E\) (W/m2), ambient air temperature \(T_{a}\) (C) and wind speed \(WS\) (m/s). Model output is cell temperature \(T_{C}\). Model parameters depend both on the module construction and its mounting. Parameters are provided in 1 for open (freestanding) and close (insulated) mounting configurations, , and are coded for convenience in TEMPERATURE_MODEL_PARAMETERS. The heat loss factors provided represent the combined effect of convection, radiation and conduction, and their values are experimentally determined.

Mounting

\(U_{c}\)

\(U_{v}\)

freestanding

29.0

0.0

insulated

15.0

0.0

References

1

“PVsyst 6 Help”, Files.pvsyst.com, 2018. [Online]. Available: http://files.pvsyst.com/help/index.html. [Accessed: 10- Dec- 2018].

2

Faiman, D. (2008). “Assessing the outdoor operating temperature of photovoltaic modules.” Progress in Photovoltaics 16(4): 307-315.

Examples

>>> from pvlib.temperature import pvsyst_cell, TEMPERATURE_MODEL_PARAMETERS
>>> params = TEMPERATURE_MODEL_PARAMETERS['pvsyst']['freestanding']
>>> pvsyst_cell(1000, 10, **params)
37.93103448275862